Test
Supply Chain Security, Resilience & Industry Trends
Executive Summary
Supply chains have become a strategic focus area for utilities and critical infrastructure operators. Globally sourced hardware, software, and connected technologies introduce cybersecurity, operational, and geopolitical risks that can impact reliability, resilience, and business operations.
At the same time, utilities are investing in advanced visibility and decision-support capabilities including Artificial Intelligence (AI), Supply Chain Control Towers, Digital Twins, and supplier-risk monitoring. These capabilities help organizations improve situational awareness, identify disruptions earlier, and strengthen long-term resilience.
| Area | Potential Impact |
|---|---|
| Reliability | Equipment shortages, supplier outages, and logistics disruptions can affect maintenance schedules, project timelines, and grid modernization efforts. |
| Cybersecurity | Third-party technologies may introduce new attack surfaces, software vulnerabilities, and unauthorized access pathways. |
| Operations | Limited visibility into suppliers and dependencies can delay the identification and resolution of operational disruptions. |
| Resilience | Organizations require the ability to anticipate, withstand, and recover from changing operational, geopolitical, and market conditions. |
Key Supply Chain Risks
Technology & Asset Assurance
Recent industry assessments have highlighted the importance of understanding communications protocols, data flows, vendor connectivity, and remote access capabilities associated with modern energy technologies.[2]
Examples include:
- Cellular communications modules
- Wi-Fi connectivity
- Bluetooth interfaces
- Vendor remote-access capabilities
- Undocumented communications pathways
Why It Matters
For utilities, uncertainty surrounding deployed technologies can complicate asset management, cybersecurity monitoring, incident response, and overall operational awareness. The challenge is often less about a specific technology and more about understanding exactly what has been deployed and how it communicates.
Software Supply Chain Risk
Modern utility operations depend on software vendors, cloud providers, embedded firmware, open-source components, and third-party integrators.
A compromise of a trusted software supplier can potentially affect multiple organizations simultaneously. As software ecosystems grow increasingly complex, visibility into software dependencies becomes more important.
EPRI's Technical Assessment Methodology (TAM) emphasizes evaluating attack surfaces, identifying security gaps, and validating security controls throughout technology deployments.[3]
Geopolitical & Supplier Risk
Global supply chains remain vulnerable to geopolitical developments, manufacturing concentration, transportation constraints, and evolving trade regulations.
Examples include:
- Trade restrictions and tariffs
- Export controls
- Semiconductor shortages
- Critical mineral dependencies
- Transportation disruptions
These events can affect equipment availability, increase lead times, and delay infrastructure investments across the utility sector.
| Risk Area | Examples |
|---|---|
| Cybersecurity | Third-party compromise, ransomware, software supply chain attacks |
| Technology | Undocumented communications, firmware integrity concerns, unsupported products |
| Geopolitical | Export controls, tariffs, regional instability |
| Logistics | Shipping delays, port disruptions, inventory shortages |
Supply Chain Cybersecurity
As utilities continue their digital transformation efforts, cybersecurity considerations increasingly extend beyond organizational boundaries and into supplier ecosystems.
Industry supply chain security programs focus on understanding software integrity, vendor access, communications pathways, and architectural risks before technologies are deployed.[4]
EPRI's Defensible Network Architectures guidance provides criteria for securely deploying operational technologies and reducing exposure to unauthorized access pathways.[5]
Leading Practices
- Supplier cybersecurity assessments
- Software Bills of Materials (SBOMs)
- Hardware Bills of Materials (HBOMs)
- Vendor access reviews
- Multi-Factor Authentication (MFA)
- Network segmentation
- Continuous supplier monitoring
Artificial Intelligence in Supply Chains
Artificial Intelligence is helping organizations move beyond reactive supply chain management by improving forecasting, disruption analysis, inventory planning, and supplier-risk identification.
Current applications include:
- Demand forecasting
- Inventory optimization
- Supplier risk monitoring
- Predictive maintenance
- Transportation optimization
- Procurement analytics
As supply chains become increasingly complex, digital tools are being adopted to improve operational awareness and support planning activities across utility operations.[6]
Emerging Trend: Agentic AI
Industry leaders are evaluating AI systems capable of performing approved actions on behalf of supply chain personnel. Potential applications include supplier evaluation, inventory balancing, logistics optimization, and disruption-response activities.
While still emerging, Agentic AI is expected to become a major area of investment over the next several years.
Supply Chain Visibility & Control Towers
A Supply Chain Control Tower provides a centralized view of suppliers, inventory, logistics networks, external risks, and operational dependencies.
Rather than relying on disconnected data sources, organizations can monitor critical supply chain activities from a single operational picture and identify disruptions earlier.
The same industry drivers accelerating adoption of digital twins, advanced analytics, and operational visibility platforms are also increasing demand for comprehensive supplier awareness and dependency mapping.[7]
| Capability | Business Value |
|---|---|
| Real-Time Visibility | Improves awareness of inventory, suppliers, shipments, and operational dependencies. |
| Risk Monitoring | Identifies supply chain disruptions, supplier issues, and emerging risks earlier. |
| Decision Support | Enables faster and more informed operational and procurement decisions. |
| Executive Reporting | Provides leadership with a consolidated view of supply chain performance and risks. |
Key Question
Can we identify and respond to supply chain disruptions before they impact operations?
Digital Twins & Scenario Planning
Digital Twins create virtual representations of suppliers, transportation networks, inventory, and operational dependencies.
These environments allow organizations to evaluate potential disruptions before they occur and better understand downstream operational impacts.
As utilities adapt to increasing levels of inverter-based resources, distributed energy resources, and interconnected technologies, advanced modeling and simulation capabilities are becoming essential tools for planning, resilience analysis, and operational decision-making.[8]
Common scenarios include:
- Supplier failures
- Transportation disruptions
- Severe weather events
- Equipment shortages
- Grid modernization delays
Recommendations
| Area | Recommended Actions |
|---|---|
| Procurement | Require SBOMs and HBOMs, assess supplier security practices, review remote-access capabilities, and validate vendor security programs. |
| Visibility | Maintain supplier inventories, map critical dependencies, improve traceability, and understand technology communications pathways. |
| Monitoring | Continuously assess supplier risks, geopolitical developments, software vulnerabilities, and emerging threats. |
| Security | Eliminate default credentials, implement MFA, restrict remote access, validate firmware integrity, and segment networks. |
Emerging Trends (2026–2027)
Utilities continue to monitor several technologies and practices that may significantly influence future supply chain operations, resilience, and risk management.
| High Priority | Emerging Areas |
|---|---|
|
|
Digital Product Passports (DPPs)
Digital Product Passports are emerging as a mechanism for improving product traceability and lifecycle transparency. Driven largely by international regulatory initiatives, DPPs may influence future procurement, supplier reporting, asset lifecycle management, and supply chain visibility programs.
References
- ↑ EPRI Supply Chain Assessment Research Program
- ↑ EPRI Security Design Architecture Review: Solar Inverters (3002029720)
- ↑ EPRI Technical Assessment Methodology (3002012752)
- ↑ EPRI Security Design Architecture Review: Solar Inverters (3002029720)
- ↑ EPRI Defensible Network Architectures: Criteria for Secure OT Deployment in Power Systems (3002027430)
- ↑ EPRI Inverter-Based Resources and Grid Interconnection Research Area
- ↑ EPRI Supply Chain Assessment Research Program
- ↑ EPRI Inverter-Based Resources and Grid Interconnection Research Area
EPRI Resources
- EPRI Supply Chain Assessment Research Program
- EPRI Security Design Architecture Review: Solar Inverters (3002029720)
- EPRI Technical Assessment Methodology (3002012752)
- EPRI Defensible Network Architectures: Criteria for Secure OT Deployment in Power Systems (3002027430)
- EPRI Inverter-Based Resources and Grid Interconnection Research Area
Related Topics
- Inverter-Based Resources (IBRs)
- Battery Energy Storage Systems (BESS)
- Supply Chain Cybersecurity
- Operational Technology (OT) Security
- Digital Twins
- Artificial Intelligence
- Supplier Risk Management