Test
Exposure Management & Security Monitoring Platforms
Executive Summary
As Operational Technology (OT), Industrial Control Systems (ICS), and enterprise environments become increasingly interconnected, organizations require continuous visibility into assets, vulnerabilities, threats, and operational risk.
Exposure Management and Security Monitoring platforms help organizations identify unmanaged assets, prioritize remediation activities, improve threat detection, and accelerate incident response. These capabilities support both cybersecurity operations and operational resilience programs.
EPRI guidance continues to emphasize asset visibility, communications awareness, architecture understanding, and continuous monitoring as foundational elements of cybersecurity programs within utility environments.[1]
| Objective | Business Value |
|---|---|
| Visibility | Understand what assets exist and where risk is located. |
| Prioritization | Focus remediation efforts on the highest-risk assets and vulnerabilities. |
| Threat Detection | Improve detection of suspicious or malicious activity. |
| Operations | Reduce response time and improve situational awareness. |
Platform Overview
Organizations commonly deploy a combination of asset visibility, threat detection, exposure management, threat intelligence, and vulnerability management platforms. While capabilities overlap, platforms often have different strengths depending on operational requirements and cybersecurity objectives.
Dragos
Overview
Dragos is an OT-focused cybersecurity platform designed specifically for industrial and critical infrastructure environments. The platform emphasizes asset visibility, industrial threat detection, incident response, and operational risk awareness.
Key Capabilities
- Comprehensive OT asset discovery and inventory
- Industrial protocol awareness
- Behavioral and anomaly-based threat detection
- Visibility into PLCs, HMIs, DCS, SCADA systems, and IEDs
- Threat hunting and incident response support
- OT vulnerability and exposure management
Strengths
| Area | Benefit |
|---|---|
| OT Visibility | Deep visibility into industrial assets, protocols, and communications. |
| Threat Detection | Behavioral analytics designed specifically for OT environments. |
| Investigations | Strong support for threat hunting and industrial incident response. |
| Integrations | Integrates with SIEM platforms such as Splunk and Microsoft Sentinel. |
Typical Use Cases
- Substation monitoring
- Generation facility monitoring
- Threat hunting
- OT asset inventory modernization
- Industrial incident response
Trellix
Overview
Trellix combines security operations, threat intelligence, exposure management, endpoint visibility, and investigation workflows to provide centralized cyber risk monitoring across enterprise environments.
Organizations commonly leverage Trellix for centralized monitoring, exposure management, threat intelligence, and vulnerability prioritization.
Key Capabilities
- Automated asset discovery
- Exposure and vulnerability management
- Integrated threat intelligence
- Security investigations and incident response workflows
- Centralized management using ePolicy Orchestrator (ePO)
- Security monitoring and analytics
Strengths
| Area | Benefit |
|---|---|
| Threat Intelligence | Visibility into emerging threats and adversary activity. |
| Asset Discovery | Identifies unmanaged and previously unknown assets. |
| Operations | Supports centralized security operations workflows. |
| Automation | Enables automated security investigation and response activities. |
Limitations
| Consideration | Impact |
|---|---|
| Licensing Dependencies | Advanced functionality may require additional licensing or platform integrations. |
| OT Visibility | OT-specific context may not be as deep as solutions purpose-built for industrial environments. |
| Legacy Systems | Endpoint-based visibility may be limited in highly segmented or unsupported OT networks. |
Typical Use Cases
- Enterprise exposure management
- Vulnerability prioritization
- Threat intelligence operations
- SOC monitoring
- Investigation and response workflows
Platform Comparison
| Capability | Dragos | Trellix |
|---|---|---|
| OT Asset Visibility | High | Moderate |
| Industrial Protocol Awareness | High | Limited |
| Threat Intelligence | High | High |
| Threat Hunting | High | High |
| Vulnerability Management | Moderate | High |
| Security Operations Integration | High | High |
| Enterprise Asset Visibility | Moderate | High |
| OT Incident Response | High | Moderate |
Utility Considerations
Utilities operating OT and critical infrastructure environments often require specialized visibility into industrial protocols, communications pathways, and operational dependencies.
EPRI research continues to emphasize understanding communications flows, architecture dependencies, external connectivity, and operational context as essential cybersecurity capabilities.[6]
In practice:
- OT-focused platforms such as Dragos provide deeper industrial visibility and threat detection.
- Enterprise-focused platforms such as Trellix provide broader exposure management and centralized security operations capabilities.
- Many organizations deploy both OT-specific and enterprise security monitoring tools to achieve comprehensive visibility.
Recommended Practices
| Focus Area | Recommendation |
|---|---|
| Visibility | Establish comprehensive inventories across both IT and OT environments. |
| Risk Prioritization | Focus remediation efforts on critical assets and exploitable vulnerabilities. |
| Monitoring | Continuously monitor for abnormal behavior, threats, and emerging exposures. |
| Integration | Share asset inventory and exposure data with SIEM and SOC platforms. |
| Governance | Align exposure management activities with enterprise risk management programs. |
References
- ↑ EPRI Defensible Network Architectures: Criteria for Secure OT Deployment in Power Systems (3002027430)
- ↑ Dragos Platform Overview
- ↑ Dragos Platform Documentation
- ↑ Trellix ePolicy Orchestrator (ePO)
- ↑ Trellix Security Platform
- ↑ EPRI Security Design Architecture Review: Solar Inverters (3002029720)
Source Links
Industry References
- EPRI Defensible Network Architectures: Criteria for Secure OT Deployment in Power Systems (3002027430)
- EPRI Security Design Architecture Review: Solar Inverters (3002029720)
- NIST Cybersecurity Framework
- CISA Cybersecurity Performance Goals
Platform References
Related Topics
- OT Asset Visibility
- Exposure Management
- Vulnerability Management
- Threat Intelligence
- Operational Technology (OT) Security
- Security Operations Centers (SOC)
- Industrial Control Systems (ICS)
- Threat Hunting
- OT Monitoring